MACHEREY-NAGEL – Products for thin layer chromatography (TLC/HPTLC)

Macherey-Nagel Macherey-Nagel

MACHEREY-NAGEL and Chromatography

We provide optimal and reliable solutions for your laboratory work in sample preparation, method development and routine analysis.

About Us

MACHEREY-NAGEL Chromatography – complete solutions for your analysis

From a pioneer in chromatography to a full-range supplier of laboratory consumables, we supply laboratories around the world with HPLC, GC and SPE columns, TLC/HPTLC plates, autosampler vials, closures and more.

Macherey-Nagel image Macherey-Nagel image

MACHEREY-NAGEL offers a versatile range of ready-to-use TLC and HPTLC layers, which are the result of 50 years of continuous research and development in thin layer chromatography.


The comprehensive range of TLC products from MACHEREY-NAGEL includes:

Macherey-Nagel

TLC/HPTLC glass plates

ADAMANT, SIL G or SIL HD are silica layers on glass backing. It’s hard to imagine a laboratory without our reliable TLC and HPTLC glass plates.

Macherey-Nagel

ALUGRAM and POLYGRAM TLC/HPTLC sheets are easy to handle, lightweight and flexible.

High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results. Moreover these TLC sheets are easy to cut with scissors.

Macherey-Nagel

Accessories

In addition to high quality TLC plates and sheets, we offer staining reagents and developing chambers, as well as introductory sets for educational purposes.

TLC Backings & Supports
Macherey-nagel Macherey-nagel

TLC/HPTLC plates and sheets consist of an adsorbent stationary phase on a backing support.

MACHEREY-NAGEL offers three different backings:
 

  • Glass plates
  • Aluminium sheets
  • Polyester sheets

Properties of TLC backings

Glass Plates

  • Thickness (approx.): 1.3mm
  • Weight and storage requirements: high
  • Torsional strength: ideal
  • Temperature stability: high
  • Susceptible to breakage: yes
  • Can be cut with scissors: no
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: depends on phases (layer)

Glass plates are robust, heat proof and chemically resistant to all common mobile phases and visualisation reagents. They are the traditional option in TLC/HPTLC and are widely used in the pharmaceutical sector and other laboratory environments.


Aluminium Sheets - ALUGRAM Xtra

  • Thickness (approx.): 0.15mm
  • Weight and storage requirements: low
  • Torsional strength: relatively high
  • Temperature stability: high
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: low
  • Suitability for aqueous detection reagents: ALUGRAM: low to moderate, ALUGRAM Xtra: moderate to high

Aluminium sheets are easy to handle, lightweight and flexible. High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results, even with 100% aqueous detection reagents. Moreover, ALUGRAM Xtra sheets are easy to cut with scissors. No flaking of silica occurs!


Polyester Sheets – POLYGRAM

  • Thickness (approx.): 0.2mm
  • Weight and storage requirements: low
  • Torsional strength: low
  • Temperature stability: maximum 185°C
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: good

Polyester sheets are easy to handle, lightweight and flexible, and can also be cut with scissors. Developed POLYGRAM sheets can also be stored for documentation in laboratory notebooks.

TLC and HPTLC
Macherey_Nagel

Features of modern TLC/HPTLC

The success of thin layer chromatography as a highly efficient microanalytical separation method is based on a large number of advantageous properties:

  • High sample throughput in a short time
  • Suitable for screening tests
  • Pilot procedure for HPLC and Flash chromatography
  • After separation the analytical information can be stored for a longer period of time (the TLC ready-to-use layer acts as storage medium for data)
  • Separated substances can be subjected to subsequent analytical procedures (e.g., IR, MS) at a later date
  • Rapid and cost-efficient optimisation of the separation due to easy change of mobile and stationary phase
Macherey-nagel Macherey-nagel

'TLC' and 'HPTLC' are both widely used terms in laboratory environments, but what is the difference? At MACHEREY-NAGEL, we define 'HPTLC' where at least one of the following criteria is being fulfilled:

  • Layers with particle size 2–10 μm
  • Layers prefixed with 'Nano'
  • Modified layers

Narrow fractionation of HPTLC silica particles allows:

  • Sharper separations
  • Shorter developing times
  • Shorter migration distances
  • Smaller samples needed
  • Increased detection sensitivity (compared to TLC)
Products

Macherey-Nagel™ MN 713 Grade Filter Paper, Folded

Cover tables, benchtops and shelves to absorb spilled/splashed liquids. Macherey-Nagel™ MN 713 Grade Filter Paper, Folded is a smooth, thick technical filter paper with medium filtration speed for use in general lab applications and to protect surfaces from a range of substances. X100 Filter paper sheets MN 713 size: 15x21 cm (DIN A-5)

Macherey-Nagel™ CHROMABOND™ XTR Polypropylene SPE Columns

Designed for consistently high quality from batch to batch. Macherey-Nagel™ CHROMABOND™ XTR Polypropylene SPE Columns include Kieselguhr phase for liquid-liquid extractions. Columns feature a large pore size and high pore volume for use with highly viscous aqueous solutions. Volumes from 1–45mL. X100 CHROMABOND columns XTR volume: 1 mL, 250 mg Kieselgur for volumes up to 0.25 mL material: PP

Macherey-Nagel™ Chromafil™ Xtra PTFE Syringe Filters

Filter nonpolar liquids and gases. Chromafil™ Xtra PTFE Syringe Filters with polytetrafluoroethylene hydrophobic membrane. X100 Chromafil Xtra PTFE-20/25

Macherey-Nagel™ TLC Spray Visualization Reagents

Used for postchromatographic detection reactions in thin-layer chromatography. Macherey-Nagel™ TLC Spray Visualization Reagents are a selection of frequently used spray reagents that are suited for spraying or dipping TLC plates. Glass laboratory sprayer (mfr. no. 814101) sold separately. X1 4-(Dimethylamino)-benzaldeh., 100 mL

Macherey-Nagel™ Nano-SIL Unmodified HPTLC Silica Layers on Glass Plates

Separate mixtures with sharp separations, short developing times and short migration distances. Nano-SIL Unmodified HPTLC Silica Layers on Glass Plates have an increased detection sensitifvity compared to SIL G plates. X50 TLC precoated plates Nano-SIL-20 size: 10x20 cm

Macherey-Nagel™ Polygram CEL 300 PEI/UV254 Polyester Sheets

X25 POLYGRAM sheets CEL 300 PEI/UV254 size: 20 x 20 cm

Macherey-Nagel™ Polyester Sheets Polygram CEL 300 TLC Micro-Set M

X200 POLYGRAM sheets CEL 300 size: 4 x 8 cm 4 x 50

Macherey-Nagel™ Nylon Polyamide Adsorbent

1KG Polyamide TLC 6 1000 g in plastic container

Macherey-Nagel™ Standard SIL G Silica Layers on Glass Plates

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on glass plates come in a variety of plate sizes and layer thicknesses. Select a fluorescent indicator and choose from a variety of pack sizes. X100 TLC precoated plates SIL G-25 UV 254 size: 5x20 cm

Macherey-Nagel™ Glass Laboratory Sprayer

Used as an accessory in thin layer chromatography applications. Macherey-Nagel™ Glass Laboratory Sprayer includes a 100mL, clear glass conical flask with a sprayer-stopper assembly and rubber bulb/tubing. Glass from laboratory sprayer with rubber bulb

Macherey-Nagel™ Durasil-25 TLC Plate

X50 TLC precoated plates DURASIL-25 size: 10x20 cm

Macherey-Nagel™ Chiralplate™ for TLC Enantiomer Separation

Resolve a wide variety of enantiomers. Chiralplate™ for TLC Enantiomer Separation consists of a special layer available on glass plates with fluorescent indicator. X25 TLC precoated plates CHIRALPLATE size: 20x20 cm

Macherey-Nagel™ Standard SIL G Silica Layers on Polygram™ polyester sheets

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on Polygram™ polyester sheets come in a variety of sizes. Select fluorescent indicator and choose from a variety of pack sizes. X25 POLYGRAM sheets SIL G/UV254 size: 20 x 20 cm

Macherey Nagel Nanocolor Tube Test

Fast, easy-to-use, bar-coded, predosed test tubes for testing a variety of water and wastewater analysis parameters. NANO Sulfate LR 200

Macherey-Nagel™ Collection Rack

X5 CHROMABOND Mulit 96 Collection rack for PP-Vessels (twelve 8-well-strips) volume: 96x1.0 mL

Macherey-Nagel™ Nucleogel™ HPLC Column

HPLC column for special application VA 50/4.6 NUCLEOGEL SCX 1000-8 Länge: 50 mm, ID: 4,6 mm

Macherey-Nagel™ Nucleodur™ C18 ec HPLC VP Guard Columns Cartridge

VarioPrep HPLC guard column cartridge VP 10/8 NUCLEODUR C18 ec Length: 10 mm, ID: 8 mm

Macherey-Nagel™ Polygoprep™ 300 to 50 C18

POLYGOPREP 300-50 C18 (Packung a 1000 gr)

Macherey-Nagel™ Standard Silica 60 Adsorbents

Silica gel 60 particle size: 0,04-0,063 mm pack of 25 kg in plastic bag in

Macherey-Nagel™ Nucleodur™ 100-5 NH2-RP EC Standard Column

EC HPLC column EC 150/4.6 NUCLEODUR 100-5 NH2-RP length: 150 mm, ID: 4.6 mm

Macherey-Nagel™ Chromabond™ Glass Empty SPE Column

X50 CHROMABOND Reservoir 3 mL, glass volume: 3 mL, with 2 glass fibre filterelements

Macherey-Nagel™ Chromofil™ Polyester Syringe Filter

Filter polar or nonpolar solvents. Chromofil™ PET Polyester Syringe Filter is hydrophilic for multipurpose applications and comes color coded. Einmalfilter PET-45/25,PET,Por.:0,45 µm, D=25 mm,Farbcode:farblos/orange (VE=100St)

Macherey-Nagel™ Adapters for Chromabond™ SPE Columns

For individual packing of SPE columns with Chromabond™ adsorbents. Macherey-Nagel™ Adapters for Chromabond™ SPE Columns are available in several materials for a variety of empty column types and capacities. CHROMABOND Adaptor (PVDF) for combination of 1,3, 6 ML glass columns, with disposable syringes,

Macherey-Nagel™ Chromabond™ HR-XCW Polypropylene SPE Column

CHROMABOND Columns HR-XCW weakmixed-mode polymer-based cation exchanger volume:

Macherey-Nagel™ Adamant™ Unmodified Standard Silica Layers for TLC, UV254

Increase separation efficiency and maximize resolution during TLC (thin-layer chromatography). Adamant™ Unmodified Standard Silica Layers for TLC, UV254, are available on glass plates with an optimized binder system and UV indicator. X100 ADAMANT TLC precoated plates UV 254 thickness of layer: 0.25 mm size: 2.5x7.5 cm

Macherey-Nagel™ Nucleosil™ C18 PPN Reversed Phase HPLC Column, 5 μm, 4 mm x 250 mm

Column Format: Analytical Column; Pore Size: 100 Å; Column Phase: Reversed Phase EC HPLC column EC 250/4 NUCLEOSIL 100-5 C18 PPN length: 250 mm, ID: 4 mm

Macherey-Nagel™ Glass RP-2/UV254 TLC Plate

X25 TLC precoated plates RP-2 UV254 (silanized silica gel) thickness: 0.25 mm, size: 20x20 cm

Macherey-Nagel™ ALUGRAM™ Xtra SIL G Aluminum Sheets

Stable in almost all organic solvents and in purely aqueous eluents. Macherey-Nagel™ ALUGRAM™ Xtra SIL G Aluminum Sheets are unmodified standard silica layers on aluminium for use in TLC. Feature outstanding wettability and improved cutting properties. X50 ALUGRAM Xtra-Sheets SIL G size: 5 x 20 cm

Macherey-Nagel™ Chromabond™ Polypropylene Empty LV SPE Column

X50 CHROMABOND empty polypropylene LV columns with PE filterelements, 15 mL for 200/500 mg

  spinner