MACHEREY-NAGEL – Products for thin layer chromatography (TLC/HPTLC)

Macherey-NagelMacherey-Nagel

MACHEREY-NAGEL and Chromatography

We provide optimal and reliable solutions for your laboratory work in sample preparation, method development and routine analysis.

About Us

MACHEREY-NAGEL Chromatography – complete solutions for your analysis

From a pioneer in chromatography to a full-range supplier of laboratory consumables, we supply laboratories around the world with HPLC, GC and SPE columns, TLC/HPTLC plates, autosampler vials, closures and more.

Macherey-Nagel imageMacherey-Nagel image

MACHEREY-NAGEL offers a versatile range of ready-to-use TLC and HPTLC layers, which are the result of 50 years of continuous research and development in thin layer chromatography.


The comprehensive range of TLC products from MACHEREY-NAGEL includes:

Macherey-Nagel

TLC/HPTLC glass plates

ADAMANT, SIL G or SIL HD are silica layers on glass backing. It’s hard to imagine a laboratory without our reliable TLC and HPTLC glass plates.

Macherey-Nagel

ALUGRAM and POLYGRAM TLC/HPTLC sheets are easy to handle, lightweight and flexible.

High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results. Moreover these TLC sheets are easy to cut with scissors.

Macherey-Nagel

Accessories

In addition to high quality TLC plates and sheets, we offer staining reagents and developing chambers, as well as introductory sets for educational purposes.

TLC Backings & Supports
Macherey-nagelMacherey-nagel

TLC/HPTLC plates and sheets consist of an adsorbent stationary phase on a backing support.

MACHEREY-NAGEL offers three different backings:
 

  • Glass plates
  • Aluminium sheets
  • Polyester sheets

Properties of TLC backings

Glass Plates

  • Thickness (approx.): 1.3mm
  • Weight and storage requirements: high
  • Torsional strength: ideal
  • Temperature stability: high
  • Susceptible to breakage: yes
  • Can be cut with scissors: no
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: depends on phases (layer)

Glass plates are robust, heat proof and chemically resistant to all common mobile phases and visualisation reagents. They are the traditional option in TLC/HPTLC and are widely used in the pharmaceutical sector and other laboratory environments.


Aluminium Sheets - ALUGRAM Xtra

  • Thickness (approx.): 0.15mm
  • Weight and storage requirements: low
  • Torsional strength: relatively high
  • Temperature stability: high
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: low
  • Suitability for aqueous detection reagents: ALUGRAM: low to moderate, ALUGRAM Xtra: moderate to high

Aluminium sheets are easy to handle, lightweight and flexible. High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results, even with 100% aqueous detection reagents. Moreover, ALUGRAM Xtra sheets are easy to cut with scissors. No flaking of silica occurs!


Polyester Sheets – POLYGRAM

  • Thickness (approx.): 0.2mm
  • Weight and storage requirements: low
  • Torsional strength: low
  • Temperature stability: maximum 185°C
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: good

Polyester sheets are easy to handle, lightweight and flexible, and can also be cut with scissors. Developed POLYGRAM sheets can also be stored for documentation in laboratory notebooks.

TLC and HPTLC
Macherey_Nagel

Features of modern TLC/HPTLC

The success of thin layer chromatography as a highly efficient microanalytical separation method is based on a large number of advantageous properties:

  • High sample throughput in a short time
  • Suitable for screening tests
  • Pilot procedure for HPLC and Flash chromatography
  • After separation the analytical information can be stored for a longer period of time (the TLC ready-to-use layer acts as storage medium for data)
  • Separated substances can be subjected to subsequent analytical procedures (e.g., IR, MS) at a later date
  • Rapid and cost-efficient optimisation of the separation due to easy change of mobile and stationary phase
Macherey-nagelMacherey-nagel

'TLC' and 'HPTLC' are both widely used terms in laboratory environments, but what is the difference? At MACHEREY-NAGEL, we define 'HPTLC' where at least one of the following criteria is being fulfilled:

  • Layers with particle size 2–10 μm
  • Layers prefixed with 'Nano'
  • Modified layers

Narrow fractionation of HPTLC silica particles allows:

  • Sharper separations
  • Shorter developing times
  • Shorter migration distances
  • Smaller samples needed
  • Increased detection sensitivity (compared to TLC)
Products
Macherey-Nagel™ MN 713 Grade Filter Paper, Folded

Macherey-Nagel™ MN 713 Grade Filter Paper, Folded

Cover tables, benchtops and shelves to absorb spilled/splashed liquids. Macherey-Nagel™ MN 713 Grade Filter Paper, Folded is a smooth, thick technical filter paper with medium filtration speed for use in general lab applications and to protect surfaces from a range of substances. X100 Filter paper sheets MN 713 size: 15x21 cm (DIN A-5)

Macherey-Nagel™ CHROMABOND™ XTR Polypropylene SPE Columns

Macherey-Nagel™ CHROMABOND™ XTR Polypropylene SPE Columns

Designed for consistently high quality from batch to batch. Macherey-Nagel™ CHROMABOND™ XTR Polypropylene SPE Columns include Kieselguhr phase for liquid-liquid extractions. Columns feature a large pore size and high pore volume for use with highly viscous aqueous solutions. Volumes from 1–45mL. X30 CHROMABOND columns XTR volume: 45 mL: 8300 mgKieselgur for volumes up to 10 mL material: PP

Macherey-Nagel™ Chromafil™ Xtra  PTFE Syringe Filters

Macherey-Nagel™ Chromafil™ Xtra PTFE Syringe Filters

Filter nonpolar liquids and gases. Chromafil™ Xtra PTFE Syringe Filters with polytetrafluoroethylene hydrophobic membrane. X100 Chromafil Xtra PTFE-20/25

Macherey-Nagel™ TLC Spray Visualization Reagents

Macherey-Nagel™ TLC Spray Visualization Reagents

Used for postchromatographic detection reactions in thin-layer chromatography. Macherey-Nagel™ TLC Spray Visualization Reagents are a selection of frequently used spray reagents that are suited for spraying or dipping TLC plates. Glass laboratory sprayer (mfr. no. 814101) sold separately. 100ML Iron (III) chloride solution

Macherey-Nagel™ Nano-SIL Unmodified HPTLC Silica Layers on Glass Plates

Macherey-Nagel™ Nano-SIL Unmodified HPTLC Silica Layers on Glass Plates

Separate mixtures with sharp separations, short developing times and short migration distances. Nano-SIL Unmodified HPTLC Silica Layers on Glass Plates have an increased detection sensitifvity compared to SIL G plates. X50 TLC precoated plates Nano-SIL-20 size: 10x20 cm

Macherey-Nagel™ Polygram CEL 300 PEI/UV254 Polyester Sheets

Macherey-Nagel™ Polygram CEL 300 PEI/UV254 Polyester Sheets

X25 POLYGRAM sheets CEL 300 PEI/UV254 size: 20 x 20 cm

Macherey-Nagel™ Polyester Sheets Polygram CEL 300 TLC Micro-Set M

Macherey-Nagel™ Polyester Sheets Polygram CEL 300 TLC Micro-Set M

X200 POLYGRAM sheets CEL 300 size: 4 x 8 cm 4 x 50

Macherey-Nagel™ Nylon Polyamide Adsorbent

Macherey-Nagel™ Nylon Polyamide Adsorbent

1KG Polyamide TLC 6 1000 g in plastic container

Macherey-Nagel™ Glass Laboratory Sprayer

Macherey-Nagel™ Glass Laboratory Sprayer

Used as an accessory in thin layer chromatography applications. Macherey-Nagel™ Glass Laboratory Sprayer includes a 100mL, clear glass conical flask with a sprayer-stopper assembly and rubber bulb/tubing. Glass from laboratory sprayer with rubber bulb

Macherey-Nagel™ Durasil-25 TLC Plate

Macherey-Nagel™ Durasil-25 TLC Plate

X50 TLC precoated plates DURASIL-25 size: 10x20 cm

Macherey-Nagel™ Standard SIL G Silica Layers on Glass Plates

Macherey-Nagel™ Standard SIL G Silica Layers on Glass Plates

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on glass plates come in a variety of plate sizes and layer thicknesses. Select a fluorescent indicator and choose from a variety of pack sizes. X25 TLC precoated plates SIL G-25 UV 254+366 size: 20x20 cm

Macherey-Nagel™ Chiralplate™ for TLC Enantiomer Separation

Macherey-Nagel™ Chiralplate™ for TLC Enantiomer Separation

Resolve a wide variety of enantiomers. Chiralplate™ for TLC Enantiomer Separation consists of a special layer available on glass plates with fluorescent indicator. X25 TLC precoated plates CHIRALPLATE size: 10x20 cm

Macherey Nagel Nanocolor Tube Test

Macherey Nagel Nanocolor Tube Test

Fast, easy-to-use, bar-coded, predosed test tubes for testing a variety of water and wastewater analysis parameters. NANO Sulfate LR 200

Macherey-Nagel™ Standard SIL G Silica Layers on Polygram™ polyester sheets

Macherey-Nagel™ Standard SIL G Silica Layers on Polygram™ polyester sheets

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on Polygram™ polyester sheets come in a variety of sizes. Select fluorescent indicator and choose from a variety of pack sizes. X200 POLYGRAM-sheets SIL G/UV254 size: 2.5x7.5 cm

Macherey-Nagel™ Optima™ 1701 High Performance GC Capillary Column

Macherey-Nagel™ Optima™ 1701 High Performance GC Capillary Column

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 25 m,

Macherey-Nagel™ Chrombond™ RS 120 NH2 Polypropylene Flash Column

Macherey-Nagel™ Chrombond™ RS 120 NH2 Polypropylene Flash Column

CHROMABOND columns Flash RS 120 filled with: NH2 filling: 130 g Material: PP

Macherey-Nagel™ C18 Ec F Adsorbent

Macherey-Nagel™ C18 Ec F Adsorbent

CHROMABOND Sorbenz C 18 ec f (VE=100gr)

Macherey-Nagel™ Nano Durasil-20 TLC Plate

Macherey-Nagel™ Nano Durasil-20 TLC Plate

X50 HPTLC-plates Nano-DURASIL-20 size: 10 x 20 cm

Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID

Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID

Designed for use in gas chromatography. Macherey-Nagel™ PERMABOND™ CW 20 M Capillary Columns, 0.32mm ID are composed of 20,000 Da polyethylene glycol. These polar phase columns are recommended for solvent analysis and alcohols, and are suitable for use with aqueous solutions. Capillary column PERMABOND CW 20 M ID: 0.32 mm, film thickness: 0.5 µm length: 50 m

Macherey-Nagel™ Optima™ 240 GC Capillary Column

Macherey-Nagel™ Optima™ 240 GC Capillary Column

Capillary column OPTIMA-240 ID: 0.32 mm, film thickness: 0.35 µm length: 30 m,

Macherey-Nagel™ C2 Spe Adsorbent

Macherey-Nagel™ C2 Spe Adsorbent

100GR CHROMABOND Sorbent C2 (Dimethyl) in glass container

Macherey-Nagel™ Optima™ 1 MS Accent GC Capillary Column

Macherey-Nagel™ Optima™ 1 MS Accent GC Capillary Column

Capillary column OPTIMA-1 MS Accent ID: 0.32 mm, film thickness: 0.25 µm length: 30 m

Macherey-Nagel™ Nucleodur™ C18 Isis Analytical HPLC EC Column

Macherey-Nagel™ Nucleodur™ C18 Isis Analytical HPLC EC Column

EC HPLC column EC 50/2 NUCLEODUR C18 Isis, 5 µm length: 50 mm, ID: 2 mm

Macherey-Nagel™ Optima™ 5 MS GC Capillary Column

Macherey-Nagel™ Optima™ 5 MS GC Capillary Column

Capillary column OPTIMA-5 MS ID: 0.2 mm, film thickness: 0.20 µm length: 12 m,

Macherey-Nagel™ Chromabond™ PCA Polypropylene SPE Column

Macherey-Nagel™ Chromabond™ PCA Polypropylene SPE Column

X50 CHROMABOND columns PCA volume: 3 mL, content of sorbent: 500 mg material: PP

Macherey-Nagel™ Nucleodur™ 100-5 CN Analytical EC Standard Column

Macherey-Nagel™ Nucleodur™ 100-5 CN Analytical EC Standard Column

EC HPLC column EC 250/4 NUCLEODUR 100-5 CN-RP length: 250 mm, ID: 4 mm

Macherey-Nagel™ Nucleodur™ C18 Analytical EC Standard Column

Macherey-Nagel™ Nucleodur™ C18 Analytical EC Standard Column

Use EC standard columns for analytical HPLC (High Performance Liquid Chromatography). Nucleodur™ C18 Analytical EC Standard Columns come in a wide variety of lengths and internal diameters. EC HPLC column EC 150/4 NUCLEODUR C18 Pyramid, 5 µm length: 150 mm, ID: 4 mm

Macherey-Nagel™ Chromabond™ SiOH Polypropylene SPE Column

Macherey-Nagel™ Chromabond™ SiOH Polypropylene SPE Column

X50 CHROMABOND Columns SiOH volume: 3 mL, contentof sorbent: 500 mg material: PP

Macherey-Nagel™ Manual Crimper

Macherey-Nagel™ Manual Crimper

Verschliesszange N 11

  spinner