MACHEREY-NAGEL – Products for thin layer chromatography (TLC/HPTLC)

Macherey-Nagel Macherey-Nagel

MACHEREY-NAGEL and Chromatography

We provide optimal and reliable solutions for your laboratory work in sample preparation, method development and routine analysis.

About Us

MACHEREY-NAGEL Chromatography – complete solutions for your analysis

From a pioneer in chromatography to a full-range supplier of laboratory consumables, we supply laboratories around the world with HPLC, GC and SPE columns, TLC/HPTLC plates, autosampler vials, closures and more.

Macherey-Nagel image Macherey-Nagel image

MACHEREY-NAGEL offers a versatile range of ready-to-use TLC and HPTLC layers, which are the result of 50 years of continuous research and development in thin layer chromatography.


The comprehensive range of TLC products from MACHEREY-NAGEL includes:

Macherey-Nagel

TLC/HPTLC glass plates

ADAMANT, SIL G or SIL HD are silica layers on glass backing. It’s hard to imagine a laboratory without our reliable TLC and HPTLC glass plates.

Macherey-Nagel

ALUGRAM and POLYGRAM TLC/HPTLC sheets are easy to handle, lightweight and flexible.

High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results. Moreover these TLC sheets are easy to cut with scissors.

Macherey-Nagel

Accessories

In addition to high quality TLC plates and sheets, we offer staining reagents and developing chambers, as well as introductory sets for educational purposes.

TLC Backings & Supports
Macherey-nagel Macherey-nagel

TLC/HPTLC plates and sheets consist of an adsorbent stationary phase on a backing support.

MACHEREY-NAGEL offers three different backings:
 

  • Glass plates
  • Aluminium sheets
  • Polyester sheets

Properties of TLC backings

Glass Plates

  • Thickness (approx.): 1.3mm
  • Weight and storage requirements: high
  • Torsional strength: ideal
  • Temperature stability: high
  • Susceptible to breakage: yes
  • Can be cut with scissors: no
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: depends on phases (layer)

Glass plates are robust, heat proof and chemically resistant to all common mobile phases and visualisation reagents. They are the traditional option in TLC/HPTLC and are widely used in the pharmaceutical sector and other laboratory environments.


Aluminium Sheets - ALUGRAM Xtra

  • Thickness (approx.): 0.15mm
  • Weight and storage requirements: low
  • Torsional strength: relatively high
  • Temperature stability: high
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: low
  • Suitability for aqueous detection reagents: ALUGRAM: low to moderate, ALUGRAM Xtra: moderate to high

Aluminium sheets are easy to handle, lightweight and flexible. High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results, even with 100% aqueous detection reagents. Moreover, ALUGRAM Xtra sheets are easy to cut with scissors. No flaking of silica occurs!


Polyester Sheets – POLYGRAM

  • Thickness (approx.): 0.2mm
  • Weight and storage requirements: low
  • Torsional strength: low
  • Temperature stability: maximum 185°C
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: good

Polyester sheets are easy to handle, lightweight and flexible, and can also be cut with scissors. Developed POLYGRAM sheets can also be stored for documentation in laboratory notebooks.

TLC and HPTLC
Macherey_Nagel

Features of modern TLC/HPTLC

The success of thin layer chromatography as a highly efficient microanalytical separation method is based on a large number of advantageous properties:

  • High sample throughput in a short time
  • Suitable for screening tests
  • Pilot procedure for HPLC and Flash chromatography
  • After separation the analytical information can be stored for a longer period of time (the TLC ready-to-use layer acts as storage medium for data)
  • Separated substances can be subjected to subsequent analytical procedures (e.g., IR, MS) at a later date
  • Rapid and cost-efficient optimisation of the separation due to easy change of mobile and stationary phase
Macherey-nagel Macherey-nagel

'TLC' and 'HPTLC' are both widely used terms in laboratory environments, but what is the difference? At MACHEREY-NAGEL, we define 'HPTLC' where at least one of the following criteria is being fulfilled:

  • Layers with particle size 2–10 μm
  • Layers prefixed with 'Nano'
  • Modified layers

Narrow fractionation of HPTLC silica particles allows:

  • Sharper separations
  • Shorter developing times
  • Shorter migration distances
  • Smaller samples needed
  • Increased detection sensitivity (compared to TLC)
Products

Macherey-Nagel™ Quantofix™ Peroxide 25 Semi-quantitative Test Strips

Ideal to test low levels of peroxide in solutions.  Macherey Nagel™ Quantofix™ Peroxide 25 Semi-quantitative Test Strips use an easy dip-and-read procedure and provide reliable results within 15 seconds. X100 Test sticks QUANTOFIX Peroxide 25 semi,

Macherey-Nagel™ Quantofix™ Peroxide 1000 Test Strip Kits

Allows for the quick and easy determination of peroxide levels in solutions. Macherey Nagel™ Quantofix™ Peroxide 1000 Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Peroxide 1000 semi,

Macherey-Nagel™ Optima™ 240 GC Capillary Column

Capillary column OPTIMA-240 ID: 0.32 mm, film thickness: 0.35 µm length: 30 m,

Macherey-Nagel™ C18 Ec F Adsorbent

CHROMABOND Sorbenz C 18 ec f (VE=100gr)

Macherey-Nagel™ Nano Durasil-20 TLC Plate

X50 HPTLC-plates Nano-DURASIL-20 size: 10 x 20 cm

Macherey-Nagel™ Silicone Septa

Silicon-Septa N 12, weich AD: 12 mm, Dicke: 3 mm,(VE=50Stck.)

Macherey-Nagel™ Alugram™ RP-18 W/UV254 Modified Silica Phase

For use in normal or reverse phase HPTLC. Macherey-Nagel™ Alugram™ RP-18 W/UV254 Modified Silica Phase are aluminum sheets coated with wettable layers of modified nano silica that can be developed with purely organic and organic/aqueous solvents and purely aqueous eluents. X50 ALUGRAM sheets RP-18W/UV254 size: 5 x 10 cm

Macherey-Nagel™ Manual Crimper

Verschliesszange N 11

Macherey-Nagel™ Quantofix™ Peroxide 100 Test Strip Kits

Allows for the quick and easy determination of peroxide levels in solutions. Macherey Nagel™ Quantofix™ Peroxide 100 Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Peroxide 100 semi,

Macherey-Nagel™ OPTIMA™ 35 MS Capillary Columns for GC

Features ultra-low bleed characteristics with high temperature stability. Macherey-Nagel™ OPTIMA™ 35 MS Capillary Columns for GC are chemically bonded, cross-linked silarylene phase columns with unique selectivity in the mid-polar region and excellent tubing surface deactivation. Capillary column OPTIMA-35 MS ID: 0.32 mm, film thickness: 0.25 µm length: 60 m.

Macherey-Nagel™ Lead Acetate Test Paper

Provides for the quick and easy determination of lead hydrogen sulphide in samples. Macherey Nagel™ Lead Acetate Test Paper is toxic and needs to be declared as hazardous. 5M LEAD ACETATE PAPER

Macherey-Nagel™ Chloride Complexing Agent for COD

Enables COD determination with samples containing high levels of chloride. Macherey-Nagel™ Chloride Complexing Agent for COD are used with Nanocolor™ COD Tube Tests when chloride content is above 1500mg/L Cl-. NANO CHLORIDE COMPLEXING AGENT FOR COD

Macherey-Nagel™ Nucleodur™ Phenyl/Hexyl Reversed Phase HPLC Column, 1.8 μm, 2 mm x 100 mm

Column Format: Analytical Column; Carbon Load: 10%; Pore Size: 110 Å; Column Phase: Reversed Phase EC 100/2 NUCLEODUR Phenyl-Hexyl, 100mm x 2mm1,8µm

Macherey-Nagel™ HYDRODEX™ β-PM Capillary Columns for GC

Enables many compounds to be analyzed without derivatization. Macherey-Nagel™ HYDRODEX™ β-PM Capillary Columns for GC are phases with 7 β-cyclodextrin glucose units for enantiomer separation in gas chromatography. This hydrophilic phase with short polar ligants is a chemically non-bonded phase. FS capillary column HYDRODEX BETA-PM ID: 0.25 mm,length: 50 m

Macherey-Nagel™ Polygram CEL 300 UV254 Polyester Sheets

X25 POLYGRAM sheets CEL 300 UV254 size: 20 x 20 cm

Macherey-Nagel™ ALUGRAM™ Alox N/UV254 Aluminum Sheets

Designed for use in thin layer chromatography. Macherey-Nagel™ ALUGRAM™ Alox N/UV254 Aluminum Sheets include aluminum oxide layers and a fluorescent indicator at short-wave UV (254nm). Activating the layers before use is recommended. X50 ALUGRAM sheets ALOX N/UV 254 thickness: 0,2 mm, size: 5 x 20 cm

Macherey-Nagel™ Nucleodur™ C18 Analytical EC Standard Column

Use EC standard columns for analytical HPLC (High Performance Liquid Chromatography). Nucleodur™ C18 Analytical EC Standard Columns come in a wide variety of lengths and internal diameters. EC HPLC column EC 150/4.6 NUCLEODUR C18 Gravity, 5 µm length: 150 mm, ID: 4.6 mm

Macherey-Nagel™ Nucleosil™ 100-3 C18 HPLC Columns

EC HPLC column EC 100/4.6 NUCLEOSIL 100-3 C18 Length: 100 mm, ID: 4.6 mm

Macherey-Nagel™ Nucleodur™ HILIC HPLC Column

EC HPLC column EC 30/4 NUCLEODUR HILIC, 1.8 µm length: 30 mm, ID: 4 mm

Macherey-Nagel™ Paracetamol reference solution (in ethanol)

8ML Paracetamol reference solution 8 mL

Macherey-Nagel™ Nano Silicon Glass Plates

X25 TLC precoated plates Nano-SIL C18-50 UV 254 size: 10x10 cm

Macherey-Nagel™ Optima™ 5 Performance GC Capillary Column

Capillary column OPTIMA-5 ID: 0.32 mm, film thickness: 0.1 µm length: 10 m,

Macherey-Nagel™ Nucleodur™ C18 Isis Analytical HPLC EC Column

EC HPLC column EC 50/2 NUCLEODUR C18 Isis, 5 µm length: 50 mm, ID: 2 mm

Macherey-Nagel™ Accessories for Stainless Steel HPLC Columns

Macherey-Nagel™ Accessories for Stainless Steel HPLC Columns include: plastic column end caps, capillary unions (100mm x 1/16 in. x 0.25mm), 1/16 in. nuts for connecting capillaries, and 1/16 in. ferrules. Schneidkegel passend für 1/16' Kapillar rohr(VE=5Stck.)

Macherey-Nagel™ Polygoprep™ 100 to 30 C18

POLYGOPREP 100-30 C18 (Packung a 1000 gr)

Macherey-Nagel™ Methyl-Sil Deactivated Capillary Column

Deactivated capillary without cage Methyl-Sil deactivated ID: 0.53 mm, length: 25 m

Macherey-Nagel™ Glass Chromabond™ C8 SPE Column

X30 CHROMABOND Columns C8 volume: 6 mL, content of sorbent: 500 mg material: glass

Macherey-Nagel™ VarioPrep HPLC Columns

VarioPrep HPLC column VP 125/10 NUCLEODUR C18Pyramid, 5 µm *** with adjustable Endfitting ***

Macherey-Nagel™ Untreated Capillary

FS capillary column, uncoated ID: 0,20 mm, length: 10 m

Macherey-Nagel™ Nucleodur™ 100-5 C8 EC HPLC Column

EC HPLC column EC 125/4 NUCLEODUR 100-5 C8 ec length: 125 mm, ID: 4 mm

  spinner