Enzymes and Inhibitors
Thermo Scientific™ MspI (HpaII)
The MspI (HpaII) restriction enzyme recognizes C^CGG sites and cuts best at 37°C in Tango buffer. MSPI (HPAII) 10U/UL 3000U
Invitrogen™ Anza™ 22 SmaI
Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System. Anza 22 SmaI (8000 units)
Thermo Scientific™ FastDigest NheI
Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer. 100 UL RESTRICTION ENZYME, FASTDIGEST, NHEI, CUTSG¬CTAGC, 1µL cleaves 1µg DNA in 5 minutes at 37°C
Thermo Scientific™ FastDigest Bsp120I
Cut at G^GGCCC sites with Thermo Scientific™ FastDigest™ Bsp120I, which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer (Isoschizomers: PspOMI). 200 UL RESTRICTION ENZYME, FASTDIGEST, BSP120I,cuts G¬GGCCC, 1µL cleaves 1µg DNA in 5 minutes at
Thermo Scientific™ PaeI (SphI)
The PaeI (SphI) restriction enzyme recognizes GCATG^C sites and cuts best at 37°C in B buffer (Isoschizomers: BbuI, SphI). PAEI (SPHI) 10U/UL 500U
Thermo Scientific™ Buffer BseXI
Optimize digestions with BseXI restriction enzyme using this buffer, premixed with BSA for enhanced stability. 10X BUFFER BSEXI 1ML
Thermo Scientific™ TaiI (MaeII)
Cut at ACGT^ sites with TaiI (MaeII) restriction enzyme, which performs best at 65°C in R buffer (Isoschizomers: HpyCH4IV, MaeII). TAII (MAEII) 10U/UL 400U
Thermo Scientific™ FastDigest MlyI (SchI)
Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer. Restriction enzyme, FastDigest SchI, 100µL
Thermo Scientific™ Bsp1407I (BsrGI)
Cut at T^GTACA sites with Bsp1407I (BsrGI) restriction enzyme, which performs best at 37°C in Tango buffer (Isoschizomers: BsrGI, BstAUI). BSP1407I (BSRGI) 10U/UL 1500U
Thermo Scientific™ Buffer R
Ensure the optimum reaction conditions for restriction enzymes with Thermo Scientific™ 10X Buffer R, premixed with BSA for enhanced stability. 10X BUFFER R 5X1 ML
Thermo Scientific™ SchI (MlyI)
Cut at GAGTC(5/5)^ sites with SchI (MlyI) restriction enzyme, which functions best at 37°C in Tango buffer (Isoschizomers: MlyI, PleI, PpsI, SchI). RESTRICTION ENZYME, CONVENTIONAL, SCHI (MLYI),10u/ul, cuts GAGTC(5/5)¬ at 37°C (supplied with
Thermo Scientific™ BseDI (BsaJI)
Cut at C^CNNGG sites with BseDI (BsaJI) restriction enzyme, which performs best at 55°C in Tango buffer (Isoschizomers: BsaJI, BssECI). RESTRICTION ENZYME, CONVENTIONAL, BSEDI (BSAJI),10u/ul, cuts C¬CNNGG at 55°C (supplied with 1mL
Thermo Scientific™ 50X TAE Buffer (Tris-acetate-EDTA)
Optimize electrophoresis of both genomic and large supercoiled DNA in agarose and polyacrylamide gels with Thermo Scientific™ 50X TAE Buffer (Tris-acetate-EDTA). 1 LT 50X TAE BUFFER (TRIS-ACETATE-EDTA), 1X CONCENtration includes 40 mM Tris, 20 mM acetic acid, 1
Thermo Scientific™ NcoI
The NcoI restriction enzyme recognizes C^CATGG sites and cuts best at 37°C in Tango buffer (Isoschizomers: Bsp19I). 1000 UNIT RESTRICTION ENZYME, CONVENTIONAL, NCOI,10u/uL, cuts C¬CATGG at 37°C (suppliedwith 1mL of
Thermo Scientific™ FastDigest MboI
Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer. 50 UL RESTRICTION ENZYME, FASTDIGEST, MBOI, CUTS¬GATC, 1µL cleaves 1µg DNA in 5 minutes at 37°C
Thermo Scientific™ FastDigest™ DpnI
Cut at Gm6A^TC sites with Thermo Scientific™ FastDigest™ DpnI, which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer (Isoschizomers: MalI). FASTDIGEST DPNI 50UL
Thermo Scientific™ PfoI
Cut at T^CCNGGA sites with PfoI restriction enzyme recognizes and cuts best at 37°C in Tango buffer. PFOI 10U/UL 200U
OPTIZYME™ SalI, Fisher BioReagents™
Optizyme Sal I restriction enzyme
Thermo Scientific™ BplI
Cut at ^(8/13)GAG(N)5CTC(13/8)^ sites with BplI restriction enzyme, which performs best at 37°C in Tango(+SAM) buffer. BPLI 5U/UL 500U
Thermo Scientific™ 10X Taq™
Find the right buffer to meet your specific PCR needs in these 10X Taq DNA Polymerase buffers with different compositions. X10 TAQ BUFF KCL MG 4X1.25ML
Thermo Scientific™ FastDigest TaqI
Perform single-, double- or multiple DNA digestion within 5-15 minutes with this advanced line of restriction enzymes, 100% active in one universal buffer. 400 UL RESTRICTION ENZYME, FASTDIGEST, TAQI, CUTST¬CGA, 1µL cleaves 1µg DNA in 5 minutes at 65°C
Thermo Scientific™ DpnI
Cut at Gm6A^TC sites with DpnI restriction enzyme, which performs best at 37°C in Tango buffer (Isoschizomers: MalI). DPNI 10U/UL 500U
Thermo Scientific™ FastDigest MslI (RseI)
Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer. Restriction enzyme, FastDigest RseI, 20µL
Invitrogen™ Anza™ 24 MssI
Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System. Anza 24 MssI (2000 units)
Thermo Scientific™ FastDigest Eco91I
Cut at G^GTNACC sites with Thermo Scientific™ FastDigest™ Eco91I, which performs best at 37°C in 5-15 minutes using universal FastDigest Buffer. FASTDIGEST ECO91I 200UL
Thermo Scientific™ NdeI
The NdeI restriction enzyme recognizes CA^TATG sites and cuts best at 37°C in O buffer (Isoschizomers: FauNDI). NDEI 10U/UL 500U
Thermo Scientific™ MboII
The MboII restriction enzyme recognizes GAAGA(8/7)^ sites and cuts best at 37°C in B buffer. RESTRICTION ENZYME, CONVENTIONAL, MBOII, 5U/UL,cuts GAAGA(8/7)¬ at 37°C (supplied with 1mL of
Thermo Scientific™ FastDigest HaeII (BfoI)
Perform single-, double- or multiple DNA digestion within 5-15 minutes withthis advanced line of restriction enzymes, 100% active in one universal buffer. Restriction enzyme, FastDigest BfoI, 200µL
Invitrogen™ Anza™ 91 Acc65I
Simplify traditional restriction enzyme cloning with the Invitrogen™ Anza™ Restriction Enzyme Cloning System. ANZA 91 Acc65I
Thermo Scientific™ XbaI
Cut at T^CTAGA sites with XbaI restriction enzyme, which functions best at 37°C in Tango buffer. XBAI 10U/UL 1500U