Membranes for Filtration

Merck Millipore MF-Millipore™ Mixed Cellulose Ester Membranes: 0.22μm Pore Size

Designed for a wide range of analytical and research applications. MF-Millipore™ Mixed Cellulose Ester Membranes, 0.22μm pore size are available in a range of diameters. Composed of plain, white mixed cellulose membrane.

Integra Biosciences™ Hydrophobic Membrane Filter

Protect the vacuum source during aspiration with this membrane filter. Integra Biosciences™ Hydrophobic Membrane Filters are designed for use with VACUSAFE Aspiration Systems.

Sartorius™ Midisart™ 2000 PTFE Air Filter

Designed for easy handling and maximum safety in air filtration. Sartorius™ Midisart™ 2000 PTFE Air Filter entirely eliminates moisture breakthrough because of its inherently hydrophobic PTFE membrane reinforced with polypropylene gauze. Stepped hose barb connectors ensure a simple and secure hold.

Merck Millipore Durapore™ PVDF Membrane Filters: 0.22μ Pore Size

Recommended when maximum recovery is important. Durapore™ PVDF Membranes: 0.22μ Pore Size provide high flow rates and throughput, low extractables, broad chemical compatibility and low protein binding. Available in diameters ranging from 13mm to 142mm.

Sartorius™ Polyamide (Nylon) Membrane Filters

Recommended for particle-removing filtration of water, aqueous solutions and solvents for analytical determination. Sartorius™ Polyamide (Nylon) Membrane Filters are white, non-sterile filters without grids. Choose from two pore sizes in four diameters. Bulk packed for space and cost savings.

Merck Millipore MF-Millipore™ Mixed Cellulose Ester Membranes: 0.80μm Pore Size

Designed for air monitoring, bioassays, dairy microbiology, particle monitoring and particle removal. MF-Millipore™ Mixed Cellulose Ester Membranes, 0.80μm pore size are available in a range of diameters. Composed of mixed cellulose membrane in black or white with a plain or gridded surface.

Sartorius™ Cellulose Nitrate Membrane Filters

Combines uniform pore structure with high flow and adsorption rates. Sartorius™ Cellulose Nitrate Membrane Filters are excellently suited for diagnostic kits. Non-sterile, hydrophillic filters in a variety of diameters and pore sizes are bulk-packed to save money and space.

Merck Millipore Isopore™ Polycarbonate Membrane Filters

Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.

Merck Millipore Nylon Net Filter

For use in the collection of algae and cells, particle analysis, large particulate filtration, prefiltration of solvents and paint monitoring. Nylon Net Filters are highly hydrophilic.

Merck Millipore Nylon Hydrophilic Membrane Filters

Filtration of aqueous or organic solutions

Fisherbrand™ Mixed Celluloses Esters Membranes Sterile Filter

Fisherbrand™ Mixed Celluloses Esters Membranes Sterile Filters are composed of cellulose acetate and cellulose nitrate.

BRAND™ Filter Membranes

Used with seripettor™ / QuikSip™ / accu-jet™ pro macro pipet controllers. Filter Membranes are available in 3μL capacity and provided in blister pack packaging.

GE Healthcare Whatman™ 47mm Nuclepore™ Polycarbonate Track-Etched Membranes

Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ 47mm Nuclepore™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.

Duran™ Spare Syringe Filter

Suitable filter for HPLC bottle sterile pressure equalization. Duran™ Spare Syringe Filter fits into the cap of a Duran™ HPLC bottle.

Sartorius™ Nongridded Sterile Cellulose Membrane Filters

Ensure quality control in routine microbiological filtering. Sartorius™ Nongridded Sterile Cellulose Membrane Filters are single-packed membranes used for colony counting, particle testing, microscopy and sterility testing. Choose between cellulose acetate or cellulose nitrate membranes in a variety of pore sizes.

GE Healthcare Whatman™ Regenerated Cellulose Membranes: Grade RC 55

Consists of pure cellulose without any wetting agents

Merck Millipore Durapore™ PVDF Membrane Filters: 0.45μ Pore Size

Recommended when maximum recovery is important. Durapore™ PVDF Membranes: 0.45μ Pore Size provide high flow rates and throughput, low extractables, broad chemical compatibility and low protein binding. Available in diameters ranging from 13mm to 142mm.

Sartorius™ PTFE (Polytetrafluorethylene) Membrane Filters

Filter air and gasses, even at low differential pressures. Sartorius™ PTFE (Polytetrafluorethylene) Membrane Filters are permanently hydrophobic with low adsorption and excellent chemical compatibility. Choose from four pore sizes in a variety of diameters.

Whatman™ Nuclepore™ Polycarbonate Hydrophilic Membranes

Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.

Thermo Scientific™ Nalgene™ Filter Membranes

Carry out particualte and microbial analysis with these filter membranes. Available in various forms for water quality work, cold sterilization or sample clean up.

Sartorius™ Cellulose Nitrate (CN) Membrane Filters

Ideal membrane filters for colony counting, particle testing and microscopy. Sartorius™ Cellulose Nitrate (CN) Membrane Filters provide effective retention, high flow rates and optimal colony growth.

Sartorius™ Polyethersulfone Membrane Filters

Polyethersulfone (PES) filters have a high internal porosity.

Fisherbrand™ Cellulose Membranes

Suitable for Clarification and sterilizing filtration of biological fluids . Fisherbrand™ Cellulose Membranes filters are composed of pure cellulose acetate modified to offer researchers the lowest binding filters available.

GE Healthcare Whatman™ Anodisc™ Filter Membranes

Constructed with precision pore structure and narrow pore size distribution. Whatman™ Anodisc™ Filter Membranes ensure a high level of particle removal efficiency. Captures microorganisms and particulates on the surface of the membrane for subsequent analysis.

Sartorius™ Regenerated cellulose (RC) Membrane Filters

These solvent-resistant, hydrophilic membrane filters are excellently suited for particle removal from solvents.