Dialysis and Desalting
GE Healthcare Disposable PD-10 Desalting Columns
Use for desalting and buffer exchange, as well as removal of low-molecular weight compounds. GE Healthcare Life Sciences™ Disposable PD-10 Desalting Columns provide fast, high-recovery.
Thermo Scientific™ Zeba™ Spin Desalting Columns, 7K MWCO, 0.5 mL
Effectively remove salt and other molecules (7K MWCO) from samples and attain excellent protein recovery with these centrifuge-based chromatography columns.
Spectrum™ Labs 300 kD Biotech CE Dialysis Kits
With tubing made from biologically inert and ultra-pure Biotech cellulose ester membrane
GE Healthcare PD SpinTrap™ G-25 Desalting Columns
Use for convenient and fast small-scale cleanup of proteins and other large biomolecules (>5000 Mr). GE Healthcare Life Sciences™ PD SpinTrap™ G-25 Desalting Columns provide the option of running multiple samples in parallel.
Thermo Scientific™ Zeba™ Spin Desalting Columns, 7K MWCO, 5 mL
Effectively remove salt and other molecules (7K MWCO) from samples and attain excellent protein recovery with these centrifuge-based chromatography columns.
Thermo Scientific™ Zeba™ Spin Desalting Columns, 7K MWCO, 2 mL
Effectively remove salt and other molecules (7K MWCO) from samples and attain excellent protein recovery with these centrifuge-based chromatography columns.
Thermo Scientific™ Slide-A-Lyzer™ G2 Dialysis Cassettes, 2K MWCO, 0.5 mL
Remove buffer salts and contaminants while maximizing sample recovery with these second-generation self-floating protein dialysis cassettes (2K MWCO).
Thermo Scientific™ Slide-A-Lyzer™ G2 Dialysis Cassettes, 3.5K MWCO, 0.5 mL
Remove buffer salts and contaminants while maximizing sample recovery with these second-generation self-floating protein dialysis cassettes (3.5K MWCO).
Spectrum™ Spectra/Por™ Float-A-Lyzer™ G2 Dialysis Devices
Ready-to-use and disposable, Float-A-Lyzer G2 incorporates biotech-grade cellulose ester (CE) membrane tubing into a preasembled dialysis device that is easy-to-use and provides ultimate convenience for small volume dialysis (1 to 10mL)
Thermo Scientific™ Slide-A-Lyzer™ Dialysis Cassette Kit, 3.5K MWCO, 0.5 mL
Remove buffer salts and contaminants and maximize sample recovery using this semi-permeable membrane with a 3500-dalton protein MW cut-off (MWCO).
GE Healthcare HiTrap™ Desalting Prepacked Columns
For rapid convenient desalting and buffer exchange. HiTrap™ Desalting Prepacked Columns are prepacked, ready to use column for group separation between high and low molecular weight substances.
Thermo Scientific™ SnakeSkin™ Dialysis Tubing, 10K MWCO
Perform desalting and buffer exchange for 10 to 100mL samples with this 10,000-MW cut-off (MWCO), ready-to-use form of traditional dialysis membrane tubing.
Thermo Scientific™ Slide-A-Lyzer™ G2 Dialysis Cassettes, gamma-irradiated, 10K MWCO
Remove buffer salts and contaminants while maximizing sample recovery with these second-generation self-floating protein dialysis cassettes (10K MWCO).
GE Healthcare Superdex 75 Increase Prepacked Column, 10/300 GL
Use these columns in preparative purification as well as for characterization and analysis of proteins with molecular weights between Mr 3,000 and 70,000, such as recombinant tagged proteins. GE Healthcare HisTrap™ excel Prepacked Columns feature tolerance to repeated harsh cleaning procedures at high pH ensures long column lifetime and minimizes carryover.
GE Healthcare HiTrap™ IEX HP Prepacked Columns
Use for high-resolution, small-scale protein purification. GE Healthcare Life Sciences™ HiTrap™ IEX HP Prepacked Columns are prepacked, ready-to-use Sepharose™ High Performance strong cation exchange columns.
GE Healthcare Disposable PD-10 Columns: Pk of 50 Empty Columns
Use for gravity flow purification. Disposable PD-10 Columns: Pk of 50 Empty Columns are economical, plastic columns that can be packed with a wide range of bulk media.
Thermo Scientific™ SnakeSkin™ Dialysis Tubing, 3.5K MWCO, 16 mm
Perform desalting and buffer exchange for 10 to 100mL samples with this 3500-MW cut-off (MWCO), ready-to-use form of traditional dialysis membrane tubing.
Spectrum™ Standard RC Dialysis Tubing
Multipurpose dialysis tubing is ideal for general dialysis for a variety of applications and volumes
Thermo Scientific™ Slide-A-Lyzer™ Dialysis Cassette Kit, 7K MWCO, 12 mL
Remove buffer salts and contaminants and maximize sample recovery using this semi-permeable membrane with a 7000-dalton protein MW cut-off (MWCO).
Thermo Scientific™ SnakeSkin™ Dialysis Clips
Securely close dialysis tubing up to 50mm flat diameter, including SnakeSkin Dialysis Tubing, with these sturdy, non-floating tube closures.
Spectrum™ Labs 0.1 - 0.5 kD Biotech CE Dialysis Kits
With tubing made from biologically inert and ultra-pure Biotech cellulose ester membrane
Thermo Scientific™ Zeba™ Spin Desalting Columns, 7K MWCO, 10 mL
Effectively remove salt and other molecules (7K MWCO) from samples and attain excellent protein recovery with these centrifuge-based chromatography columns.
Thermo Scientific™ Slide-A-Lyzer™ Dialysis Cassettes, 10K MWCO, 3 mL
Remove buffer salts and contaminants and maximize sample recovery using this semi-permeable membrane with a 10000-dalton protein MW cut-off (MWCO).
Thermo Scientific™ Slide-A-Lyzer™ G2 Dialysis Cassettes, 20K MWCO, 3 mL
Remove buffer salts and contaminants while maximizing sample recovery with these second-generation self-floating protein dialysis cassettes (20K MWCO).
Thermo Scientific™ Float Buoys for 0.1mL Slide-A-Lyzer™ MINI Dialysis Devices
Securely hold up to 25 small (0.1mL) Slide-A-Lyzer MINI Dialysis Devices with these low-density polyethylene (LPDE) rafts designed to dialyze a sample array.
GE Healthcare RESOURCE™ Q IEX Columns
Use for intermediate lab-scale purification and large-scale polishing of biomolecules GE Healthcare Life Sciences™ RESOURCE™ Q IEX Columns are strong anion exchanger columns.
Thermo Scientific™ Slide-A-Lyzer™ Dialysis Cassettes, 10K MWCO, 12 mL
Remove buffer salts and contaminants and maximize sample recovery using this semi-permeable membrane with a 10000-dalton protein MW cut-off (MWCO).
Spectrum Labs™ Spectra/Por™ Cellulose Regenerated Tubing Membrane
For molecular separation, protein binding studies, electrolyte removal and desalting
Thermo Scientific™ Slide-A-Lyzer™ Dialysis Cassettes, 2K MWCO, 30 mL
Remove buffer salts and contaminants and maximize sample recovery using this semi-permeable membrane with a 2000-dalton protein MW cut-off (MWCO).